Reading serial data from a P1 smart meter using a Wemos with Tasmota installed.

Tested on the following smart meters: - Kaifa MA105C - De Landis + Gyr, E350 (ZCF110)

Schematics~

The transistor makes sure that the RxD signal is converted and inverted to 3.3v

Tasmota Settings~

In the Configuration -> Configure Module page, select module Generic (18)

From the web console set the serial delimiter to 10 (newline). This makes Tasmota publish each line of the telegram separately to mqtt.

  • SerialDelimiter 10
  • SerialSend 1

For more details see serial-bridge.

Example output~

Below an example of the telegram message published (per line) to mqtt. From here your HA system can process the data required for your needs.

09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"/KFM5KAIFA-METER\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-3:0.2.8(42)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-0:1.0.0(200913101618S)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-0:96.1.1(4530303235303030303639363432393136)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:1.8.1(005779.835*kWh)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:1.8.2(005583.617*kWh)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:2.8.1(000000.000*kWh)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:2.8.2(000000.000*kWh)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-0:96.14.0(0001)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:1.7.0(00.498*kW)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:2.7.0(00.000*kW)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-0:96.7.21(00000)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-0:96.7.9(00000)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:99.97.0(1)(0-0:96.7.19)(000101000001W)(2147483647*s)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:32.32.0(00000)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:32.36.0(00000)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-0:96.13.1()\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-0:96.13.0()\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:31.7.0(002*A)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:21.7.0(00.496*kW)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"1-0:22.7.0(00.000*kW)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-1:24.1.0(003)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-1:96.1.0(4730303332353631323736373836373136)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"0-1:24.2.1(200913100000S)(04139.079*m3)\r"}
09:16:17 MQT: tele/wemos-9/RESULT = {"SerialReceived":"!F798\r"}

Description of each line~

see also DSMR 5.0 - P1 Companion Standard

Header information - {"SerialReceived":"/KFM5KAIFA-METER"}
Empty line - {"SerialReceived":""}
Version information for P1 output - {"SerialReceived":"1-3:0.2.8(42)"}
Date-time stamp of the P1 message - {"SerialReceived":"0-0:1.0.0(181227093413W)"}
Equipment identifier - {"SerialReceived":"0-0:96.1.1(4530303235303030303639363432393136)"}
electricityUsedTariff1 >> Meter Reading electricity delivered to client (Tariff 1) in 0,001 kWh - {"SerialReceived":"1-0:1.8.1(002293.192*kWh)"}
electricityUsedTariff2 >> Meter Reading electricity delivered to client (Tariff 2) in 0,001 kWh - {"SerialReceived":"1-0:1.8.2(002523.640*kWh)"}
Meter Reading electricity delivered by client (Tariff 1) in 0,001 kWh - {"SerialReceived":"1-0:2.8.1(000000.000*kWh)"}
Meter Reading electricity delivered by client (Tariff 2) in 0,001 kWh - {"SerialReceived":"1-0:2.8.2(000000.000*kWh)"}
electricityActiveTariff >> Tariff indicator electricity. The tariff indicator can also be used to switch tariff dependent loads e.g boilers. This is the responsibility of the P1 user - {"SerialReceived":"0-0:96.14.0(0002)"}
Actual electricity power delivered (+P) in 1 Watt resolution - {"SerialReceived":"1-0:1.7.0(00.474*kW)"}
Actual electricity power received (-P) in 1 Watt resolution - {"SerialReceived":"1-0:2.7.0(00.000*kW)"}
Number of power failures in any phase - {"SerialReceived":"0-0:96.7.21(00000)"}
Number of long power failures in any phase - {"SerialReceived":"0-0:96.7.9(00000)"}
Power Failure Event Log (long power failures) - {"SerialReceived":"1-0:99.97.0(1)(0-0:96.7.19)(000101000001W)(2147483647*s)"}
Number of voltage sags in phase L1 - {"SerialReceived":"1-0:32.32.0(00000)"}
Number of voltage swells in phase L1 - {"SerialReceived":"1-0:32.36.0(00000)"}
Text message max 1024 characters. - {"SerialReceived":"0-0:96.13.1()"}
Text message max 1024 characters. - {"SerialReceived":"0-0:96.13.0()"}
Instantaneous current L1 in A resolution - {"SerialReceived":"1-0:31.7.0(002*A)"}
Instantaneous active power L1 (+P) in W resolution - {"SerialReceived":"1-0:21.7.0(00.474*kW)"}
Instantaneous active power L1 (-P) in W resolution - {"SerialReceived":"1-0:22.7.0(00.000*kW)"}
Device-Type - {"SerialReceived":"0-1:24.1.0(003)"}
Equipment identifier (Gas) - {"SerialReceived":"0-1:96.1.0(4730303332353631323736373836373136)"}
GasMeterReadingFiveMinutes >> Last 5-minute value (temperature converted), gas delivered to client in m3, including decimal values and capture time - {"SerialReceived":"0-1:24.2.1(181227090000W)(02910.491*m3)"}
{"SerialReceived":"!5E3E"}

Additional info * Kaifa Meters (Dutch) * DSMR 5.0 - P1 Companion Standard