indirectly supported as configuration of Digoo NX-SP202 seems to work fine

Device can switch 2 individual plugs. It has a builtin metering sensor which measures power consumption of the sum of both.

My 2 devices I bought at Amazon have ROHS and CE signs and are officially valid for a maximum of 16A.

You can buy it at Amazon

According to the template configuration the device seems to be compatible with Digoo NX-SP202

Configuration~

Currently Slitinto is not present as separate module but DIGOO NX-SP202 seems to work. I had to adjust voltage and current with the following commands in the console * command VoltageSet 233 // measured with a multimeter * command CurrentSet 171 // known milliampere of my reference (here lightbulb of 40watts) This calibration is potentially individual for every device so I would suggest to calibrate it with a known power consuming device like a good old light bulb where the wattage is well known.

Flashing~

Disassembly~

The device has no screws but disassembling as not needed as you can flash it OTA using tuya-convert. Nevertheless one user described a method to "crack" it using a rubber hammer and then glue it together again with no visible defects.

Pinout~

Not known.

Procedure~

Here is described how to crack the device but also how to flash it OTA.

Miscellaneous~

I use metering capable devices to observe the power consumption and execute rule based behaviour on base of the consumption values.

i.e.: if the power consumption is lower than 10W for 30min (checked every 60 seconds) then switch off.

My script for this looks like this: * rule1 on Energy#Power>10 do backlog ruletimer1 1800; ruletimer2 60; rule1 off; endon * rule2 on rules#timer=1 do power2 off endon * rule3 on rules#timer=2 do rule1 on endon * rule1 on * rule2 on * rule3 on